GESE

Trung tâm báo cháy 2 Loop SIEMENS FC-1862/FC1861-A2

Danh mục:

Mô tả

Trung tâm báo cháy 2 Loop SIEMENS FC-1862/FC1861-A2

– FC1862 controller with 4 line card, max. 1008 points.

– Fulfill Chinese Standard of GB4717-2005 and GB16806-2006.

– Multi-language operation menu with windows style, easy and fast operation.

– Shortcut key (right key) for popping out operation items of device/event.

– Large memory space for up to 10000 history records, first in first out order, all events can be recorded during the operation period.

– LCD backlight Auto-off mode. When no operation or event to display within preset time, LCD backlight will be automatically turn off. When there are events / operations, LCD will light up automatically to display events and/or interlocking devices.

– 2 channels of programmable input/output (output: 40mA@24VDC, it can be programmed as general alarm output or general trouble output; input: dry contact).

– 1 channel of NAC for audible and visible device (0.5A@24VDC).

– 8 channels of interlocking function (output: 40mA @ 24VDC ) for automatic control and manual operations of control equipments.

– Efficient group programming according to different using.

– A FC186x controller can connect up to 2016 points by adding line card.

– Network bus (FC18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 controllers can be networked.

– FRT bus (FR18-BUS), the max. distance is 1000m (the twist wiring capacity is 1.0 to 1.5 mm2). Up to 32 floor repeater displays can be networked.

– Detection bus (FD18-BUS), 2-wire polarity-free, the max. distance for line resistance is 4000m, the max. distance for line capacitance is 5000m. (the twist wiring capacity is 1.0 to 1.5 mm2)

– Three user levels for different operation authority. Each user level is accessed by a pre-defined and changeable password.

– Convenient pluggable terminals with clear marks for field wiring.

– Auto-mapping function to support on commissioning task.

– Detection algorithm can be adjusted by controller according to environment, to provide high reliability of alarm and reduce false alarm.

– Programming can be done either directly on controller or through computer.

– “Sticker Method” easy for commissioning on site.

Thông số kỹ thuật

Model  FC-1862/’FC1861-A2
Max. No. of line cards 8
Max. No. of devices 2016
LCD screen 320×240 pixels, backlit
No. of programmable input/ output on mainboard 2
No. of NAC (0.5mA @24VDC) 1
Max. history records 10000
Max. distance between controllers within FC18-BUS 1000 m
Max. No. of controllers networked within FC18-BUS 16
Max. distance between a controller and a FRT/Mimic driver within FR18-BUS 1000 m
Max. No of FRT/Mimic driver connected with a controller 32
Auto-mapping function Available(only for detection line and field device)
Battery (not included) Depends on local regulation
Communication interface Special converter module
Input voltage 220 V@3A, 110 V@6A
220 V/50Hz ,110 V/60Hz
Power supply capacity 10 A@24 VDC
Dimension (In: mm) 1000×600×200
Weight (without battery) 34 Kg
Power fuse 220V:3.0 A , 110V:6.0A
Battery fuse 10.0 A (DC)
Operating temperature 0 ~ +40℃
Storage temperature -10 ~ +50 ℃
Humidity ≤95%(40±2 ℃)
Environment requirement indoor

– Xuất xứ: Trung Quốc.

– Bảo hành: 12 tháng.Trung tâm báo cháy 2 Loop SIEMENS FC-1862/FC1861-A2